The american college of cardiology recommends 500 600 square feet for the procedure area and 150 200 square feet allotted to the control room.
Cath lab control room.
Infection control healthcare epidemiology policies and procedures topic.
The cath lab a suite of three or four rooms one or two cath labs an equipment room and a control room must meet state guidelines for space and must be flexible enough to accommodate ever changing equipment.
Cardiac catheterization laboratory xcce1 99 control room cardiac catheterization xccc1 109 transesophageal echocardiograph tee room trte1 115 system component room xcca1 123 recovery room patient prep rrss1 127 guide plate symbols legend 135 section 5 appendix.
Recommended governance and role of the cath lab director including maintenance of appropriate industry relationships registry participation requirements and cost control considerations 4.
These two labs now share a central control room.
Storage clean tee probe room trte3 7.
Control room the control room should allow control panels for the imaging hemodynamic monitors.
After all this is why the cath lab exists.
Cath lab b was completed in august 2012.
Cardiac cath lab rn maureen thompson in the control room of the cath lab where procedures are documented.
The catheterization laboratory procedure room should provide ample space for the equipment in room storage and movement of the patient into and out of the room via stretcher or patient bed.
Previously patients in fremont county experiencing heart problems would need to be taken to a neighboring hospital for treatment.
We can now keep those patients here which is great for them shared sagewest cath lab director amy jensen.
At the other end is the examination room or emergency department treatment room where diagnoses and simple treatments are provided.
Cardiovascular laboratory service design guide april 15 2016 003c2b sa 011 2 of 15 2.
02 04 cardiac catheterization laboratory 02 04 policy 10 24 18 revised 1994 author page 3 of 4 during the procedure any item on the sterile field that becomes contaminated unsterile must be immediately removed and discarded.
Procedure room electrophysiology xcep1 3.
Cath lab a was completed in november 2011.
The control room is.
Decontamination tee probe room trte2 6.
Transesophageal echocardiograph tee procedure room trte1 4.
Attending physicians find this set up extremely effective as they can supervise and assist with procedures in both rooms simultaneously if needed.
Key techniques for enhancing patient satisfaction from pre procedure through post procedure 5.
The acc suggests 500 600 sq ft for the procedure area and 150 200 sq ft for the control room.
Placement of devices and supplies.